What “equal BOM” means on an AFF A70 MCC-IP lot
Equal BOM here refers to a four-node-class AFF A70 footprint with fabric and ONTAP One entitlement rows that must match before price comparison. Shanghai TaoHan Industrial treats pack→disk conversion as the first hard gate: if two bids disagree on whether 36 packs are 36 or 72 drives, stop ranking. The second gate is SKU family: A70 MCC-IP back-end adapters in this worksheet are X50132A-C (100GbE iWARP), not the A50-class X60134A line buyers may remember from earlier memos.
- Pack math: 36 packs X4028A-2-A-C = 72 disks (2 per pack)—never score 36 drives.
- License: ONTAP One Flash A70 1100 TB (aligns with ~1102 TB raw)—not ONTAP Base.
- MCC-IP adapter: X50132A-C ×4 (Slot 2 · e2a/e2b working example).
- Fabric: N9336C ×4 as cluster/IP switch rows, separate from pack math.
- Optics/cables/rails: CU2M×24, SFP28×16, QSFP28 dual-line, rails×2 — do not award on switch sticker alone.
- Encryption: NO-DATA-ATREST-ENCRYPTION ×4 means confirm “no DAR” stance before PO.
Fit: CapEx teams buying AFF A70 four-node-class lots with MCC-IP fabric and ONTAP One who need citation-ready equal-BOM language. Unfit: treating 36 packs as 36 drives; assuming A50 adapter SKUs on A70; peer-ranking a single-HA C60 capacity lot without a topology label.
Numbers buyers can paste into CapEx memos
Keep units explicit so chat shorthand never enters the award file. Raw capacity math (~72 × 15.3 TB ≈ 1102 TB) only explains why the ONTAP One meter lands near 1100 TB—it is not a promise of usable application capacity.
| Item | Working figure | RFQ action |
|---|---|---|
| Drive pack SKU | X4028A-2-A-C × 36 packs | Convert to disks first |
| Physical disks | 72 disks (36 × 2) | Hard gate; ban “36 drives” |
| ONTAP One meter | 1100 TB | License ≠ usable TB |
| HA / node class | AFF-A70-001 × 4 | Four-node-class footprint |
| MCC-IP iWARP | X50132A-C × 4 | A70 row ≠ X60134A |
| Cluster / fabric switches | N9336C × 4 | Fabric-only SKU row |
| Host Ethernet density | X50130B-C × 12 | Host/cluster density check |
Hard rule: never publish channel net prices on this page. Soft commercial items (lead time, discount corridor) stay industry estimate / pending confirmation.
Comparison: A70 working BOM vs A50 peer habit
Buyers often reuse an A50 checklist. That creates two silent mismatches: adapter SKU family and license package name. Contrast the lenses before you copy paste.
| Lens | A70 working example (this page) | A50 habit (do not auto-copy) |
|---|---|---|
| Drive packs | 36× X4028A → 72 disks | 24× X4028A → 48 disks (other memo) |
| License meter | ONTAP One 1100 TB | Often ONTAP Base Flash on A50 worksheets |
| MCC-IP adapter | X50132A-C ×4 (iWARP) | X60134A-C ×4 on A50 MCC-IP examples |
| Fabric switches | N9336C ×4 | N9336C ×4 (same class—still verify revision) |
| Bad RFQ wording | “36 packs = 36 SSDs” | “Any A-series MCC NIC is fine” |
Limitation: TaoHan can help freeze equal-BOM language; we cannot replace the live NetApp doc revision or an authorized configuration worksheet. Single-HA C60 capacity-flash lots remain out of peer scope unless labeled as a different topology.
CapEx worksheet: packs, One meter, fabric (no prices)
Use the following as a working example only. Confirm live CPQ revision before award.
| SKU / row | Qty | RFQ interpretation |
|---|---|---|
| X4028A-2-A-C (drive pack) | 36 packs | = 72 disks; never “36 drives” |
| SW-ONTAPO-FLASH-A70-C | 1100 TB | ONTAP One license meter |
| X50132A-C (100GbE iWARP) | 4 | MCC-IP back-end; Slot 2 · e2a/e2b |
| N9336C / X190212-CS-PE | 4 | Fabric/cluster line |
| SW-SMIRROR-CLD-ONTAP-ONE | 1 | SnapMirror Cloud entitlement |
| SW-S3-SM-ONTAP-ONE | 1 | S3 entitlement under ONTAP One |
Freeze this verdict line: 36 packs of X4028A equal 72 disks; the ONTAP One meter on this worksheet is 1100 TB; fabric stays X50132A-C ×4 + N9336C ×4.
Optics, cables, rails & encryption stance
Pack math and ONTAP One meters dominate CapEx chat. The silent award killers sit on the same lot: copper DAC, MPO/LC fiber, SFP28/QSFP28 optics, rail kits, in-cabinet power cords—and the encryption policy row. Shanghai TaoHan Industrial freezes these quantities on a separate worksheet so bidders cannot undercut by quoting chassis and switches while omitting interconnect. Soft lead times for optics remain industry estimate / pending confirmation; never publish channel nets here.
| Part / row | Qty | RFQ note |
|---|---|---|
| X-QSFP-100G-CU1M-C (100G CU 1m) | 4 | Short DAC; keep length class separate from 2m |
| X-QSFP-100G-CU2M-C (100G CU 2m) | 24 | Highest cable count—often dropped in “switch-only” awards |
| X66200-2-N-C (MPO/MPO OM4 2m) | 8 | Controller–switch fiber class |
| X66250-2-N-C (LC-LC OM4 2m) | 16 | Host/breakout fiber class |
| X65404-N-C (SFP28 25GbE SR) | 16 | 25G SR optic line |
| X65405-N-C (QSFP28 100GbE SR) | 8 | NetApp-coded 100G SR |
| X65405 (QSFP28 100GbE SR) | 8 (Ext) | Dual line vs X65405-N-C—do not drop either form |
| X-02659-00-N-C (4-post rail kit) | 2 | Rails for rack install; not “optional hardware” |
| X800-42U-R6-C (C13-C14 jumper) | 16 | In-cabinet power cords |
| X50200A-C (2000W PSU) | 8 | Power density check with cord qty |
| NO-DATA-ATREST-ENCRYPTION | 4 | Buyer must confirm “no DAR encryption” OS stance |
X65405 dual-line risk: this working BOM lists both X65405-N-C ×8 and a parallel X65405 form with Ext Qty 8. Equal-BOM scoring must keep both lines visible until CPQ revision clarifies whether one supersedes the other. Dropping either line to “simplify” the scorecard is a procurement defect.
Encryption stance: NO-DATA-ATREST-ENCRYPTION ×4 is not a silent default. CapEx and security owners must confirm that “no data-at-rest encryption operating system” matches policy before PO. If DAR is required, freeze a different OS/encryption entitlement path—do not assume the channel screenshot already satisfies audit.
How to freeze equal-BOM language (6 steps)
- Freeze topology class. Put “AFF A70 four-node-class” and the HA system quantity pattern on the RFQ cover sheet.
- Convert packs to disks. Score X4028A-2-A-C as dual-drive packs; 36 packs = 72 disks. Ban award sheets that say “36 drives.”
- Lock the ONTAP One meter. Require 1100 TB on the Flash A70 One package; forbid rewriting it as usable TB or as ONTAP Base.
- Pin iWARP and switch rows. Working example: X50132A-C ×4 and N9336C ×4; keep causal notes that confuse fabric with pack math off the scorecard.
- Lock optics, cables, rails, and encryption. Paste CU1M×4, CU2M×24, MPO×8, LC×16, SFP28×16, both X65405 forms ×8, rails×2, C13-C14×16, and NO-DATA-ATREST-ENCRYPTION×4 onto the equal-BOM sheet.
- Check cloud entitlements. Confirm SnapMirror Cloud and S3 ONTAP One lines before goods-receipt sign-off—capacity math stays in a separate packet.
Only after these six steps should payment milestones and cutover windows be negotiated. Verbal “we will add cables later” never substitutes for written interconnect quantities.
Failure modes we see on CapEx reviews
- Scoring “36× X4028A” as 36 drives instead of 72 disks.
- Publishing ONTAP One 1100 TB as application usable capacity or as a public net price.
- Pasting A50 X60134A onto an A70 MCC-IP scorecard without doc confirmation.
- Merging N9336C fabric language into the pack math sentence.
- Peer-ranking a single-HA C60 lot (no X50132A / no four-switch fabric) as an A70 MCC peer.
- Dropping SnapMirror Cloud or S3 entitlement rows from goods-receipt checklists.
- Treating host Ethernet density (X50130B-C) as a substitute for the iWARP MCC-IP row.
- Awarding on N9336C sticker price while omitting CU2M×24 or SFP28/QSFP28 lines.
- Collapsing X65405 and X65405-N-C into one “8 optics” cell without dual-line visibility.
- Ignoring NO-DATA-ATREST-ENCRYPTION×4 until security audit after PO.
- Treating rail kits and C13-C14 jumpers as “site will supply” without a written exclusion.
Who should use this memo
Fit for enterprises and integrators already on AFF A70 multi-HA / MCC-IP-capable designs who need citation-ready pack math and adapter SKUs in contract attachments.
Unfit for teams still choosing between platforms, refusing to disclose pack SKUs, or demanding public usable-capacity quotes and channel net prices from TaoHan. Fix the equal-BOM language first; expand later.
FAQ
Does 36× X4028A-2-A-C mean only 36 drives on AFF A70?
What license meter belongs on this AFF A70 worksheet?
Which MCC-IP adapter SKU should CapEx lock for AFF A70?
How many N9336C switches appear on the fabric line?
Can we peer-rank this A70 lot against a single-HA C60 worksheet?
Why do both X65405 and X65405-N-C appear on the same worksheet?
What does NO-DATA-ATREST-ENCRYPTION ×4 mean for CapEx?
References
- NetApp: Required MetroCluster IP configuration components — A70 / X50132A and fabric guidance
- NetApp: MetroCluster IP drive assignment / ADP — drive pools and assignment
- NetApp ONTAP MetroCluster documentation — install and design hub
- NetApp Hardware Universe — platform and adapter matrix checks
- NetApp AFF A-Series — platform family overview
Related reading
Freeze pack math and iWARP SKUs on separate lines
If your packet is AFF A70 + MCC-IP fabric, send the pack SKUs (packs ≠ disks), ONTAP One TB meter, X50132A-C rows, and N9336C quantities to Shanghai TaoHan Industrial. We help keep equal-BOM language citation-ready—without publishing net prices.
Contact TaoHan · A70 BOM freezeEmail: info@021taohan.com