Liquid Cooling / CDU / Flow

What should a Sensata FL ultrasonic flow sensor row say on a liquid-cooling tender?

A leak cable tells you the floor is wet. The FL Series, announced 22 October 2026, is how you see flow drop before that.

Quick Take

Quick Take: On 22 October 2026 Sensata announced the FL Series: ultrasonic coolant flow up to 400 L/min, accuracy up to 1% of full scale, non-intrusive, for CDUs and primary or secondary loops. A leak cable does not measure flow. No part number and no price are in the release.

If the 偏离表 stops at a leak cable, a slipping pump throttles the GPU on a dry floor. Add loop, fluid, both ceilings, and temperature yes or no. TAOHAN marks the gap within 1 business day. No Sensata stock claim. Price pending confirmation.

What fails when the quote only buys leak detection?

Quick Answer: You learn about a puddle. You do not learn that flow collapsed.

Typical scene: CDU, manifolds, leak cable, no flow point. The FL Series is the ultrasonic instrument for that point. It is not a CDU, and this page is not a kilowatt sizing exercise.

Count the miss as a throttled GPU. Too little flow overheats a cold plate before the floor is wet. Too much flow wastes pump energy. The FL Series is ultrasonic and non-intrusive, with low pressure drop, no moving parts, and readings the release says stay stable when bubbles are present. Bubbles are a sentence, not a percentage. Housing, connection, and protocol are choices. Until the seller writes them, the line is open. Temperature sensing is optional. A line that says FL Series has not bought the option. A line that says sensor with temperature has. TAOHAN does not claim Sensata stock. The 22 October date is an announcement, not a ship date. Keep the leak cable on its own line: a burst hose and a starving plate are different failures. If flow, loop, fluid, full scale, and temperature yes or no are missing, the monitoring package is half written. The mark-up takes 1 business day. Price pending confirmation. A 13% VAT special invoice does not create a part number the release did not print. The announcement date is not a warehouse date, and a missing pipe diameter stays blank until the seller writes it.

Which figures can you copy?

Quick Answer: 400 L/min and 1% of full scale. Temperature is optional.

Do not turn the portfolio sentence about electrical protection into a breaker line. Do not turn bubbles into a fraction.

What is the FL Series?

Quick Answer: A non-intrusive ultrasonic flow sensor, not a leak detector and not a CDU.

Definition: it reports how much coolant is moving. A leak cable is a smoke alarm. Flow is a speedometer. You may need both. Do not invent stainless steel, a flange, or Modbus. The release does not name them.

How do you add the row?

Quick Answer: Split leak from flow, name the loop and the fluid, copy both ceilings, temperature yes or no, name the reader.

  1. Step 1 — Separate leak and flow — Two lines.
  2. Step 2 — Name the loop — Primary, secondary, CDU, chiller, or HVAC.
  3. Step 3 — Name the fluid — Deionized water or a glycol mixture.
  4. Step 4 — Copy both ceilings — Up to 400 L/min. Up to 1% of full scale.
  5. Step 5 — Temperature yes or no — Optional in the release.
  6. Step 6 — Name the reader — PLC or BMS. Do not invent a protocol.

Who needs it?

Quick Answer: GPU loops on a CDU: flow and leak. A dry closet: neither.

  • Fit: CDU quotes that monitor only for leaks.
  • Not fit: air-cooled rooms; CDU kilowatt sizing; a PID the release did not print.

Which lines cannot be compared?

Quick Answer: Leak sold as flow, percent of reading, temperature assumed, an invented protocol or PID.

LineHiddenWrite
Leak includedNo flow pointA separate flow row
1% accurateOf reading or of full scaleUp to 1% of full scale
400 L/min as design flowCeiling versus the pipeUp to 400 L/min
Temperature assumedOption versus baseYes or no
Invented PIDNot in the 22 Oct releasePending confirmation

A leak cable and a flow sensor answer different failures. Compare those two lines, not a single phrase that says cooling is monitored.

Frequently Asked Questions

Quick Answer: Leak detection is not flow. Copy 400 L/min and 1% of full scale. Temperature is optional. No PID in the release.

Up to 400 liters per minute in the 22 October 2026 release. No pipe diameter and no part number.

No. Up to 1% of full scale. Write full scale on the 偏离表.

No. It reports liquid where it should not be. Low flow overheats a GPU before a puddle exists.

Optional. Write yes or no.

The release says digital or analog outputs and selectable protocols. It does not name Modbus. Use the seller datasheet.

No. This page claims no Sensata stock. Split 13% VAT only on a line you can book. Price pending confirmation.

References

Quick Answer: Figures are from the Sensata release dated 22 October 2026. Checked 27 October 2026.

Key Takeaway

Key Takeaway: Put FL flow on its own 偏离表 row beside the leak cable. TAOHAN marks a leak-only quote within 1 business day. No Sensata stock claim. Price pending confirmation.

Only a leak cable on the cooling quote?

Send the CDU monitoring lines. TAOHAN marks the missing flow row within 1 business day. No Sensata stock claim. Price pending confirmation.